Model NO.: YSX980D
Radiographic Ratings: Large Focal Point 20-35kv/1-300mas
Small Focal Point: 20-35kv/1-100mas
Input Power: Single Phase 220VAC, 50/60Hz
Trademark: YSENMED
Transport Package: Wooden Box
Specification: ISO certificate
Origin: China
HS Code: 9022199090
Model NO.: YSX980D
Radiographic Ratings: Large Focal Point 20-35kv/1-300mas
Small Focal Point: 20-35kv/1-100mas
Input Power: Single Phase 220VAC, 50/60Hz
Trademark: YSENMED
Transport Package: Wooden Box
Specification: ISO certificate
Origin: China
HS Code: 9022199090
Hospital High-frequency mamography X Ray Machine
Hospital High-Frequency Mamography X Ray Machine

Medical Diagnosis of Galactophore X-ray Machine (High-frequency)

X-ray Generator

Generator Type: High Frequency Inverter 40kHz

Input Power: Single phase 220VAC, 50/60Hz

Radiographic Ratings: Large Focal Point 20-35KV/1-300mAs

Small Focal Point 20-35KV/1-100mAs

Power Rating: 1.2kW

X-ray Tube

Model: Fixed anode, China Hang Zhou XD7(X791)

Focal Spot Size: Dual Focus 0.5mm

Target Material: Molybdenum (Mo)

Port Material: Beryllium (Be)

Anode Heat Storage: 63KHU

Anode Cooling: Air cooling

Filtration: Mo(0.03mm), Al(0.5mm)

Radiographic Stand

C-ARM: Vertical Movement: 60cm (70~130cm) Motorized

Rotations Deg: ± 180° Motorized (Deg. Data Display)

SID: 65cm

Cassette Image Receptor

18× 24cm

Line Voltage

220Vac@15A, Single phase

Weight 200kg

Bucky: (Optional)

Bucky Device: 18× 24cm Bucky drive mechanism

Grid Ratio: 3.5: 1, 30 Line/cm

Comfortable Compression(Optional):

When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.

Tissue Compression: Manual and Motorized (Max 20kg)

Compression Force and Thickness Data Display

Micom Control's Compression

Automatic Release

Intelligent Automatic Exposure Control (AEC) (Optional)

With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitable for and film, screen, or method of radiography.

Furthermore, this diagonosis X-ray machine greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utilizing the Auto kV.

Type: Solid-State Detector or PMT Detector

Microprocessor Control

AEC Mode: Full AEC(Auto kV)

Semi AEC (KV Select)

Manual (kV, mAs Select)

Density Adjustment: 10 density steps.
 Model  Fixed anode, X-ray tube made by joint venture
 Focal Spot Size  Double Focus 0.2mm/0.4mm
 Target Material  Molybdenum (Mo)
 Port Material  Beryllium (Be)
 Anode Heat Capacity  63KHU
 Anode Cooling  Air cooling
 Filtration  Mo(0.03mm),Al(0.5mm)

Hospital High-Frequency Mamography X Ray Machine

  Hospital High-frequency mamography X Ray Machine
Hospital High-Frequency Mamography X Ray Machine

Medical Diagnosis of Galactophore X-ray Machine (High-frequency)

X-ray Generator

Generator Type: High Frequency Inverter 40kHz

Input Power: Single phase 220VAC, 50/60Hz

Radiographic Ratings: Large Focal Point 20-35KV/1-300mAs

Small Focal Point 20-35KV/1-100mAs

Power Rating: 1.2kW

X-ray Tube

Model: Fixed anode, China Hang Zhou XD7(X791)

Focal Spot Size: Dual Focus 0.5mm

Target Material: Molybdenum (Mo)

Port Material: Beryllium (Be)

Anode Heat Storage: 63KHU

Anode Cooling: Air cooling

Filtration: Mo(0.03mm), Al(0.5mm)

Radiographic Stand

C-ARM: Vertical Movement: 60cm (70~130cm) Motorized

Rotations Deg: ± 180° Motorized (Deg. Data Display)

SID: 65cm

Cassette Image Receptor

18× 24cm

Line Voltage

220Vac@15A, Single phase

Weight 200kg

Bucky: (Optional)

Bucky Device: 18× 24cm Bucky drive mechanism

Grid Ratio: 3.5: 1, 30 Line/cm

Comfortable Compression(Optional):

When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.

Tissue Compression: Manual and Motorized (Max 20kg)

Compression Force and Thickness Data Display

Micom Control's Compression

Automatic Release

Intelligent Automatic Exposure Control (AEC) (Optional)

With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitable for and film, screen, or method of radiography.

Furthermore, this diagonosis X-ray machine greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utilizing the Auto kV.

Type: Solid-State Detector or PMT Detector

Microprocessor Control

AEC Mode: Full AEC(Auto kV)

Semi AEC (KV Select)

Manual (kV, mAs Select)

Density Adjustment: 10 density steps.
 Model  Fixed anode, X-ray tube made by joint venture
 Focal Spot Size  Double Focus 0.2mm/0.4mm
 Target Material  Molybdenum (Mo)
 Port Material  Beryllium (Be)
 Anode Heat Capacity  63KHU
 Anode Cooling  Air cooling
 Filtration  Mo(0.03mm),Al(0.5mm)

Hospital High-Frequency Mamography X Ray Machine

 

Diesel Engine Spare Parts

We introduce ourselves as the leading manufacturer of Cylinder Liners, cylinder head ,Piston Crown ,piston skirt ,valve stem,Valve Seat ,valve housing etc. since last 25years in China.
if you are having any inquiry regarding the products, please send us at your earliest.
Should you need further information please write to us, We are at your service.

Diesel Engine Spare Parts,Engine Cylinder Liner,Engine Piston,Marine Engine Spare Parts,Diesel Generator Spare Parts

ZhouShan HeCheng Machinery Co., LTD. , https://www.hcmarineparts.com