(UN2000A) Bluetooth Touchscreen Vital Sign Patient Monitor for Medical

Model NO.: UN2000A
OEM: Support
Display: 5 Inch TFT-LCD
Bluetooth: Support
Gross Weight: 1kg
Touchscreen: Yes
Etco2: Optional
Bluetooth Printer: Optional
Net Weight: 655g
Dimension: 209X;104X47.5(mm)
Trademark: Union Medical
Transport Package: Carton
Origin: China
HS Code: 9018193010
Model NO.: UN2000A
OEM: Support
Display: 5 Inch TFT-LCD
Bluetooth: Support
Gross Weight: 1kg
Touchscreen: Yes
Etco2: Optional
Bluetooth Printer: Optional
Net Weight: 655g
Dimension: 209X;104X47.5(mm)
Trademark: Union Medical
Transport Package: Carton
Origin: China
HS Code: 9018193010
(UN2000A) Bluetooth Touchscreen Patient Monitor for Medical

Model:UN2000A
Waveform:ECG and SPO2 waveforms

Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data
Build-in rechargeable Li-battery, up to 15 hours running time, support AC and DC power
Adjustable audible and visual alarms, and sensor off alarm
Long time monitoring and sleeping monitoring
Easy to carry, suitable for ambulance center, has the stand for fixing
ETCO2, FiCO2 and RR are optional


Priors
 
Storage and review data up to 3888groups via Trend Graph and Trend List
USB and Bluetooth data upload
Big font screen interface is easy to observe
Back light can be adjusted
Free advanced software are all standard on free
Optional Bluetooth printer to print the waveform and data out


Parameters

ECG

Input:5- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation



Heart Rate

Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm


SpO2

SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm


NIBP

Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those
measured by trained medical personnel using cuff and stethoscope. The MEAN value measured
using this device is equal to that measured using blood pressure measurement device. 


Temperature

Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC


EtCO2(Optional)

Measuring Range:  0~150mmHg
Resolution: 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm


Printer (optional)

Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V.  
Charge(discharge) >=1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH

Storage Operation/relative humidity:-20~60ºC/10~90%RH



(UN2000A) Bluetooth Touchscreen Vital Sign Patient Monitor for Medical
(UN2000A) Bluetooth Touchscreen Vital Sign Patient Monitor for Medical


Payment

(UN2000A) Bluetooth Touchscreen Vital Sign Patient Monitor for Medical


Shipping


Three Channels ECG Machine with Touch Screen (UN8003)


(UN2000A) Bluetooth Touchscreen Vital Sign Patient Monitor for Medical




 
(UN2000A) Bluetooth Touchscreen Patient Monitor for Medical

Model:UN2000A
Waveform:ECG and SPO2 waveforms

Features:
Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data
Build-in rechargeable Li-battery, up to 15 hours running time, support AC and DC power
Adjustable audible and visual alarms, and sensor off alarm
Long time monitoring and sleeping monitoring
Easy to carry, suitable for ambulance center, has the stand for fixing
ETCO2, FiCO2 and RR are optional


Priors
 
Storage and review data up to 3888groups via Trend Graph and Trend List
USB and Bluetooth data upload
Big font screen interface is easy to observe
Back light can be adjusted
Free advanced software are all standard on free
Optional Bluetooth printer to print the waveform and data out


Parameters

ECG

Input:5- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation



Heart Rate

Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm


SpO2

SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm


NIBP

Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those
measured by trained medical personnel using cuff and stethoscope. The MEAN value measured
using this device is equal to that measured using blood pressure measurement device. 


Temperature

Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC


EtCO2(Optional)

Measuring Range:  0~150mmHg
Resolution: 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm


Printer (optional)

Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V.  
Charge(discharge) >=1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH

Storage Operation/relative humidity:-20~60ºC/10~90%RH



(UN2000A) Bluetooth Touchscreen Vital Sign Patient Monitor for Medical
(UN2000A) Bluetooth Touchscreen Vital Sign Patient Monitor for Medical


Payment

(UN2000A) Bluetooth Touchscreen Vital Sign Patient Monitor for Medical


Shipping


Three Channels ECG Machine with Touch Screen (UN8003)


(UN2000A) Bluetooth Touchscreen Vital Sign Patient Monitor for Medical




 

Our wooden working machine use advanced technique to make motor. So there is higher & stronger power. Using longevity is more longer. Little sparkling, perfect gear noise and more accurate cutting precision.
Circular Saw have plastic motor house and aluminium motor house. Big additional handle is more safety for using. Size is 7`,8`,9`,10`,12`.
Miter saw has more accurate adjustable precision.8427U is 12` biggest blade. Vertical and level adjustable degree is 0-45degree. More higher Input power. Size is 10`,12`.
Ordital grinder size is 93x185mm, 110x100mm
Electric trimmer has higher power. Make the working is more easy and more happy.
Corner assemblying machine give more professional tools to use.
Electric Chain Saw have 1600W high power. Easy user. Don`t like gasoline Chain Saw so complex operation.

Safety rules
1. Pls read the operation manual carefully before using.
2. Before installing the blade must check the machine no-load about one minute. After installing the blade. Check the blade is installed safety and work no-load normally. If there is abnormal, pls remove the blade and install again.
3. Don`t use any broken blade. Before install, must check the blade is safe and no broken.
4. Finishing working, pls take off the power quickly.
5. Keep work area clean.
6. Finishing working, clean and pack the machine and blade. Maintenance your working machine.

Woodworking Machine

Woodworking Machine,Combination Woodworking Machine,Combined Woodworking Machine,Multi Woodworking Machine

ZHE JIANG ULITE TOOLS MANUFACTURE CO.,LTD , http://www.ulitepowertool.com