The solution after the reducer motor and the integrated machine are broken

In the process of using the motor reducer, there are occasions when the shaft is broken. First, the broken shaft of the geared motor may be a problem with its quality. In order to prevent the problem of broken shaft of the geared motor, what should we pay attention to, or what are our solutions to these problems?
1. Some applications must strictly abide by this criterion. This is not only the protection of the reducer, but also the interruption of the output shaft of the motor reducer. The main reason is that if there is a problem with the installation of the equipment, the output shaft of the reducer and its load are stuck. At this time, the overload capability of the drive motor will continue to increase the output, and thus, the output bearing of the reducer may be affected. The force exceeds twice its rated output torque and the output shaft of the reducer is broken.
Gear reducer motor manufacturers
2. During acceleration and deceleration, if the output torque of the motor reducer is more than twice the rated output torque and the acceleration and deceleration are too frequent, then the deceleration will eventually be decelerated. The machine is broken.
3. The wrong selection results in insufficient output of the gear unit. Some users mistakenly believe that as long as the rated output torque of the selected motor reducer unit meets the working requirements, it is not the case. First, the rated output torque of the motor is multiplied by the reduction ratio. The obtained value is in principle It is smaller than the rated output torque of the similar reducer provided by the product sample. Secondly, it must also consider the overload capacity of the drive motor and the maximum working torque required in practice. In theory, the maximum working torque required by the user. Must be less than 2 times the rated output torque of the reducer.
Finally, Hubei Airlines reminds everyone: When using geared geared motors, it must be installed, used, maintained, and maintained according to the operating guidelines. At the same time, if the wrong type of output produces insufficient output, the output of the reducer is too small. Axis problem, the motor reducer is a common problem, this time you can connect to the factory for maintenance, try not to disassemble your own repair.