Newborn Baby Resuscitaire Infant Radiant Warmer
Model NO.: IRW-1000
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: No
Modes: Auto
Oxygen Cylinder: No
X-ray Cassette: Yes
Tilt Angle of Bed: Stepless Adjustable
Heater Head: Adjusted
Low Pressure Aspirator: No
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
Model NO.: IRW-1000
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: No
Modes: Auto
Oxygen Cylinder: No
X-ray Cassette: Yes
Tilt Angle of Bed: Stepless Adjustable
Heater Head: Adjusted
Low Pressure Aspirator: No
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
Newborn Baby Resuscitaire Infant Radiant WarmerFeatures:
1. heat source is anti-blast infrared-tube made of microcrystal quartz
2. continuously variable mattress tilt
3. radiant head can two-directory rotate on horizon
4. X-ray cassette shelf under infant bed
5. high-bright eradiate lamp detect lightness
6. advanced microprocessor control temperature system auto-heated mode,
7. separately display set temperature and real temperature
8. 4sound-light alarm capacity: set-off, fan, sensor, over tempÂ
Specifications
Â
Environment temperature | +18ºC~+30ºC | ||
Environment relative humidity | 30ºC~75% | ||
Environment air velocity of flow | <0.3m/s | ||
Power requirement | ≤1000VA | ||
Temperature control model | Auto | ||
Temperature control range | 25ºC~37ºC | ||
Temperature override mode to | N/A | ||
Temperature sensor accuracy | ≤0.3ºC | ||
Mattress temperature uniformity | ≤2.0ºC | ||
Temperature rise time | ≤45min | ||
Heat output indicate | 0~100% | ||
Radiant box horizon angle adjust range | 0~±90°step-less | ||
Mattress Tray Size | 68cm*54cm | ||
Mattress tilt adjust range | 0~±10°step-less | ||
Shelf Max.load | 2kg | ||
Heater infrared wavelength | 1~3μm | ||
Alarms |
Power failure alarm | ||
Sensor failure alarm | |||
Over temperature alarm:≤38.0ºC |
Features:
1. heat source is anti-blast infrared-tube made of microcrystal quartz
2. continuously variable mattress tilt
3. radiant head can two-directory rotate on horizon
4. X-ray cassette shelf under infant bed
5. high-bright eradiate lamp detect lightness
6. advanced microprocessor control temperature system auto-heated mode,
7. separately display set temperature and real temperature
8. 4sound-light alarm capacity: set-off, fan, sensor, over tempÂ
Specifications
Â
Environment temperature | +18ºC~+30ºC | ||
Environment relative humidity | 30ºC~75% | ||
Environment air velocity of flow | <0.3m/s | ||
Power requirement | ≤1000VA | ||
Temperature control model | Auto | ||
Temperature control range | 25ºC~37ºC | ||
Temperature override mode to | N/A | ||
Temperature sensor accuracy | ≤0.3ºC | ||
Mattress temperature uniformity | ≤2.0ºC | ||
Temperature rise time | ≤45min | ||
Heat output indicate | 0~100% | ||
Radiant box horizon angle adjust range | 0~±90°step-less | ||
Mattress Tray Size | 68cm*54cm | ||
Mattress tilt adjust range | 0~±10°step-less | ||
Shelf Max.load | 2kg | ||
Heater infrared wavelength | 1~3μm | ||
Alarms |
Power failure alarm | ||
Sensor failure alarm | |||
Over temperature alarm:≤38.0ºC |
Latex Glove,Work Glove,Safety Glove
Fenghua Jade Motor Co., Ltd. , http://www.xwgloves.com