Hospital 8" LCD Baby Infant Incubator with Phototherapy (Baby Care 7G)
Model NO.: Baby Care 7G
Air Temperature Control Range: 25oc-37oc (Over Mode 37-39oc)
Accuracy of Skin Temperature Sensor: +-0.2oc
Humidity Display Range: 0%Rh~99%Rh
Operating Temperature Range: 20oc~30oc
Power Supply: AC220V-230V/50Hz or AC110V-120V/50-60Hz
Model Name: Baby Infant Incubator
Trademark: Poweam
Transport Package: Wooden Case
Specification: ISO, CE
Origin: China
HS Code: 90189090
Model NO.: Baby Care 7G
Air Temperature Control Range: 25oc-37oc (Over Mode 37-39oc)
Accuracy of Skin Temperature Sensor: +-0.2oc
Humidity Display Range: 0%Rh~99%Rh
Operating Temperature Range: 20oc~30oc
Power Supply: AC220V-230V/50Hz or AC110V-120V/50-60Hz
Model Name: Baby Infant Incubator
Trademark: Poweam
Transport Package: Wooden Case
Specification: ISO, CE
Origin: China
HS Code: 90189090
Hospital 8" LCD Baby Infant Incubator with Phototherapy (Baby Care 7G)Two control modes: Air mode and baby mode controlled by micro-computer
The information can be stored, consulted and indicated by the LCD display screen
Humidity and oxygen concentration display and servo control
>37C temperature set function
The air circle with outlet in both front and back
Brushless DC motor with low noise
Double wall hood, air circulation system in the way of air outlet from front and back
X-ray cassette under the bassinet
Integrated water reservoir in the shape of drawer which can be autoclaved
Inclination of bassinet is adjustable
The height of whole unit can be adjusted
Failure alarm indication
RS-232 connector
Disposable skin temperature sensor is optional
Below is tech spec of baby infant incubator:
Power supply |
AC220V-230V/50Hz or AC110V-120V/50-60Hz |
Max. Power output | 1300VA |
Mode of control | Air mode and baby mode controlled by micro-computer |
Air temperature control range | 25ºC-37ºC (over mode 37-39ºC) |
Baby temperature control range | 34ºC-37ºC (over mode 37-38ºC) |
Accuracy of skin temperature sensor | +-0.2ºC |
The temperature difference between incubator temperature and average incubator temperature (under steady temperature condition) | <=0.5ºC |
Temperature uniformity | <=0.8ºC (mattress is on the horizontal position) |
Inclination of the bassinet | +-12 |
Noise inside hood | <=45dB(A) |
Failure alarm | over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, sensor box position alarm, tank position alarm, system alarm and so on |
Humidity display range | 0%RH~99%RH |
Humidity control range | 0%RH~90%RH |
Accuracy of humidity | +-10%RH |
Indication range of oxygen concentration | 0%~99% |
Control range of oxygen concentration | 20%~60% |
Control Accuracy of oxygen concentration | +-4% |
Range of weight | 100-8000g |
Resolution for weight indication | 1g |
Accuracy of weight | +-1% |
Operating temperature range | 20ºC~30ºC |
Ambient air movement rate | <0.3m/s |
Standard Configuration | Main body (including baby compartment, base, controller, I.V. POLE AND TRAY), the sensor box, skin temperature sensor and vertical height adjustment stand(VHA stand) |
Optional Configuration | Weighing system and monitor shelf, Disposable skin temperature sensor |
Hospital 8" LCD Baby Infant Incubator with Phototherapy (Baby Care 7G)
Two control modes: Air mode and baby mode controlled by micro-computer
The information can be stored, consulted and indicated by the LCD display screen
Humidity and oxygen concentration display and servo control
>37C temperature set function
The air circle with outlet in both front and back
Brushless DC motor with low noise
Double wall hood, air circulation system in the way of air outlet from front and back
X-ray cassette under the bassinet
Integrated water reservoir in the shape of drawer which can be autoclaved
Inclination of bassinet is adjustable
The height of whole unit can be adjusted
Failure alarm indication
RS-232 connector
Disposable skin temperature sensor is optional
Below is tech spec of baby infant incubator:
Power supply |
AC220V-230V/50Hz or AC110V-120V/50-60Hz |
Max. Power output | 1300VA |
Mode of control | Air mode and baby mode controlled by micro-computer |
Air temperature control range | 25ºC-37ºC (over mode 37-39ºC) |
Baby temperature control range | 34ºC-37ºC (over mode 37-38ºC) |
Accuracy of skin temperature sensor | +-0.2ºC |
The temperature difference between incubator temperature and average incubator temperature (under steady temperature condition) | <=0.5ºC |
Temperature uniformity | <=0.8ºC (mattress is on the horizontal position) |
Inclination of the bassinet | +-12 |
Noise inside hood | <=45dB(A) |
Failure alarm | over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, sensor box position alarm, tank position alarm, system alarm and so on |
Humidity display range | 0%RH~99%RH |
Humidity control range | 0%RH~90%RH |
Accuracy of humidity | +-10%RH |
Indication range of oxygen concentration | 0%~99% |
Control range of oxygen concentration | 20%~60% |
Control Accuracy of oxygen concentration | +-4% |
Range of weight | 100-8000g |
Resolution for weight indication | 1g |
Accuracy of weight | +-1% |
Operating temperature range | 20ºC~30ºC |
Ambient air movement rate | <0.3m/s |
Standard Configuration | Main body (including baby compartment, base, controller, I.V. POLE AND TRAY), the sensor box, skin temperature sensor and vertical height adjustment stand(VHA stand) |
Optional Configuration | Weighing system and monitor shelf, Disposable skin temperature sensor |
Bulk of Rabies Vaccine For Human Use(semi-Finished Products)
1. The standard for internal control is higher than national standard. The Rabies Vaccine has high potency and has good immunogenicity.
2. The vaccine shows good safety with low ratio in adverse reaction. The product is suitable for large scope vaccination in exposure area.
Bulk Of Rabies Vaccine,Mild Bulk Of Rabies Vaccine,Stable Rabies Vaccine
Changchun BCHT Biotechnology Co. , http://www.ccbcht.com